Adobe
Acrobat Reader is required for downloading and printing these
specifications. If you do not have Acrobat Reader download
the free software now. |
|
|
|
BTX
Window Automation
Product Specifications
Engineered Shading Systems
|
| |
|
|
|
| Section
430- Sky Control DS-100 |
Part
1 - General
|
| 1.01 |
Abstract:
|
|
A.
|
Scope
of work is to provide cellular and pleated fabric shades for glass
skylights or hard-to-reach windows that are capable of operating on
any slope in any orientation, operated by BTX manual or motorized
lift systems along with, accessories, attachment hardware, and equipment
necessary to complete satisfactory installation. |
| 1.02 |
Submittals:
|
|
A.
|
Manufacturing
literature to describe assembly, materials, installation instructions,
and specific data. Include any pertinent wiring diagrams. |
|
B.
|
Shop
drawings are to include but are not limited to, all components, fasteners,
and installation methods. |
|
C.
|
Window
systems are custom-built based on measurements taken in the field.
|
| 1.03 |
Quality
Assurance: |
|
A. |
Manufacturer's
Qualification |
|
|
1. |
BTX
Window Automation is the original manufacturer of a unique line of
motorized headrail systems, electronic shading devices and controls.
|
|
B.
|
A
qualified installer or sub-contractor shall perform installation. |
|
C.
|
Installation
shall conform to Local and National Building Code and any applicable
local standards. |
|
D.
|
Sample
system may be provided upon Architect's request and BTX authorization.
|
| 1.04
|
Delivery,
Storage and Handling: |
|
A. |
Systems
to be delivered to installation site or to installer intact in original
manufacturer's custom-built containers. |
|
B. |
Systems
shall be operated under normal room temperature range, humidity, and
operating conditions. |
| 1.05 |
Warranty:
|
|
A. |
Provide
BTX limited warranty of two (2) years from date of shipment against
defects in materials and workmanship of motors and hardware. Electronic
and electrical controls are warranted against defects in materials
and workmanship for two (2) years from date of shipment from the factory. |
|
|
|
|
Part
2 - Products
|
| 2.01
|
Manufacturer:
|
|
A. |
BTX
Window Automation
10827 Alder Circle
Dallas, TX 75238 USA
(800) 422-8839 |
| 2.02 |
Standards: |
|
A. |
The
maximum size for lightweight, single cell fabric shall be 80 sq. ft.
For double cell and room-darkening fabric, the maximum size shall
be 50 sq. ft. For bottom or side-to-side stack the maximum shall be
35 sq. ft. |
|
B.
|
The
maximum system width shall be 96 inches. The minimum width shall be
12 inches. The minimum depth for flush mount shall be 2 inches. |
|
C.
|
The
following configurations shall require a stationary support cord:
Lightweight cellular fabric with widths over 48 inches. Pleated or
medium weight cellular fabric widths over 36 inches. Heavy weight
cellular fabric widths over 18 inches. |
| 2.03 |
Components: |
|
A. |
Motor
shall operate on 12V DC. Power shall be supplied via transformer that
plugs into standard 110v outlet and requires no electrician or special
wiring. |
|
B. |
Head
rail, sill, and side rails shall be made of extruded aluminum. |
|
C. |
The
upper and lower pulley blocks along with left and right end caps shall
be made from engineering grade injection molded plastic. |
|
D. |
Cording
shall be made from aircraft cable. Motorized systems shall use nylon
coated aircraft cable. |
| 2.04
|
Controls:
|
|
A.
|
The
switching device to activate the system shall be either a BTX switch
for hardwired control or the BTX IR remote control. Multiple systems
shall be controlled either individually or by BTX group controllers. |
|
|
|
|
Part
3 - Execution
|
| 3.01 |
Inspection
and Preparation: |
|
A.
|
Qualified
installer shall be responsible for window measurements prior to installation,
installation conditions, and preparation of all mounting surfaces.
|
|
B.
|
The
power supplied shall be 110v AC outlet. Wiring between primary switch
and selected control units shall be in accordance with manufacturer's
wiring schematics and specifications. All on site wiring shall be
provided by the owner. |
| 3.02
|
Installation:
|
|
A. |
System
installation shall be in accordance with BTX mounting instructions.
|
| 3.03
|
Maintenance:
|
|
A.
|
Lift
system components should not require routine maintenance under normal
operating conditions. |
|
B.
|
For
care of blinds and shade materials refer to manufacturer's care and
use directions. |